Tailor-made plants for wastewater and industrial water treatment
SERVICES OFFERED
- Customized solution design based on concentrations, flow rates, space requirements, local regulations and reagent availability.
- Manufacture of the BIOBOX solution and transport to destination.
- On-site installation, connections (water, electricity) and commissioning.
- Knowledge transfer for O&M.
- Remote follow-up and advice.
- Leasing/renting contract for the BIOBOX plant.

BIOBOX
Nitrate
Technology
- Puremust-sn®: Denitrification via biofiltration, anoxic and heterotrophic. Transformation of NO3- into N2 gas. Dosage of M.O. stoichiometric, real-time process control: NO3-, ORP, pH, Temperature, O2.
- Final refining filtration.
- Pre and post biofilter UV disinfection.
key parameters
- EBTC = 30 min per 100 mg NO3-/l.
- OPEX 50% lower than Reverse Osmosis.
- Concentrations of up to 2000 mg NO3- per liter.
- Low energy consumption.
BIOBOX
Iron and manganese
Technology
- Removal by adsorption and particulate filtration of iron and manganese in the cationic state, using Filtralite® Pure HC and Filtralite® HMR.
- Process control: O2, pH, ORP.
key parameters
- Low water pre-conditioning requirement.
- Long duration of the useful life of the material.
BIOBOX
Arsenic
Technology
- Removal by adsorption of dissolved Arsenic, using Filtralite® HMR-As.
- Process control: O2, pH, ORP.
key parameters
- Low water pre-conditioning requirement.
- Adsorption of As in the material until the end of its useful life.
- Long life of Filtralite HMR-As.
- Low OPEX
- High As concentrations.
BIOBOX
Ammonium
Technology
- Nitrification via aerobic and autotrophic biofiltration.
- Transformation of NH4+ into NO3-.
- Real-time process control: Alkalinity, ORP, pH, Temperature, O2.
- Pre and post biofilter UV disinfection.
key parameters
- High loads of NH4+ per volume unit.
- Alkalinity dosage.
- Very low OPEX.
- Reduced energy consumption.
BIOBOX
Organic Matter/DQO
Technology
- Anaergy®: Biofiltration in 2 stages: heterotrophic anoxic and heterotrophic aerobic.
- Water with high concentrations of COD/BOD.
- Real-time process control: ORP, pH, Temperature, O2.
key parameters
- High loads of COD (>5000 mg/l) with HRT for hours.
- Low process costs.
- Reduced surface area required.
BIOBOX
Fluorides
Technology
- Physical-chemical removal, using Filtralite® HC 0.8-1.6
- Process control: O2, pH, ORP.
key parameters
- Low water pre-conditioning requirement.
- 2 filtration steps.
- Very low operating cost.
BIOBOX
Heavy Metals
Technology
- Removal by adsorption of metallic cations, using Filtralite® HMR.
- Process control: O2, pH, ORP.
key parameters
- Wide spectrum of application: Cd, Zn, Ni, Cu, Fe, Pb…
- Long duration of the useful life of the material.
- OPEX 40% to alternative processes.
BIOBOX
Phosphorus
Technology
- Water treatment without pollutant rejections or water waste.
- Operating cost below 0.15 USA/ M3
- SGS certified
key parameters
- No polluting waste
- No water waste
- SGS certified
BIOBOX
Turbidity
Technology
- Compliance with the new draft RD (2021). Turbidity < 0.3 NTU.
- Raw water with high TSS content (>40 mg/l).
- High filtration velocities (>15 m/h) maintaining quality. Reduced Footprint.
- Simple process with low energy demand and low OPEX.
key parameters
- Low process costs.
- Reduced footprint
- High filtration rates
Combination of BIOBOX technologies
For water treatment with combined contaminant matrices, it is possible to integrate different BIOBOX solutions. Depending on the flow rate to be treated and the pollutant concentrations, a solution with a single container (2 integrated BIOBOX technologies) or in two containers (operating in series with separate BIOBOX technologies) can be considered. Also, for medium and large flow rates, modular solutions are designed to operate in parallel from the same power supply.
By way of example, 2 cases are presented:
CASE 1
Simultaneous presence of dissolved arsenic and nitrates. Arsenic is removed first (BIOBOX Arsenic), and then nitrate concentration is eliminated with BIOBOX Nitrates technology.

CASE 2
WWTP without nitrogen removal system. Combination of BIOBOX Nitrates and BIOBOX Ammonium technologies, working in series, with recirculation of the treated effluent in second stage.

We are here to help you!
We can solve all your doubts
Información básica sobre protección de datos:
Responsable: Ingeniería de Obras Zaragoza S.L.
Finalidad: Gestionar el mensaje de información y dar respuesta al mensaje recibido.
Legitimación: Consentimiento del interesado.
Destinatarios: No se cederán a terceros los datos recibidos, excepto por imperativo legal.
Derechos: Acceder, rectificar y suprimir los datos, así como otros derechos como se explica en la información adicional.
Información adicional: Puede consultar la información adicional y detallada sobre Protección de Datos en este enlace: política de privacidad.